ultraviolet water purification equipment, air
sanitizing and surface disinfection systems, and uv
germicidal lamps
|
|

|
The Standard of Excellence in
Ultraviolet |
|
|
You are here > Home
Page > Monozone™
Ozone Generators |
| |
|
|
   Monozone™
Ozone Generator |
 |
|
|
Monozone™
Ozone Generator
Installation and Maintenance |
Installation and Operating
Caution:
Monozone™
Ozone Generators produce high
quality ozone without oxides and
nitrogen as is produced in
Corona Discharge type of Ozone
Generator.
Monozone™
Ozone Generators are intended
for use in scientific research
and industrial and commercial
ozonation applications and
are not intended for use in
occupied areas. (The Food
and Drug Administration
prohibits any device that
generates or causes an
accumulation of more than 0.05
P.P.M. of ozone in the
atmosphere of an enclosed space
intended to be occupied by
people for extended periods of
time.)
Before performing maintenance on
your Monozone™
Ozone Generator, be sure to
unplug the unit from the wall
socket to prevent unnecessary
exposure to ultraviolet rays or
hazard of electrical shock.
Even short exposure to direct or
strongly reflected ultraviolet
germicidal rays will cause
painful eye irritation and
reddening of the skin. Personnel
subject to such exposure must
wear suitable face shield,
gloves and clothing.
MAINTENANCE:
A regular cycle of cleaning the
lamp and filter should be
established based on visual
inspection and experience. The
frequency of cleaning will vary
with the conditions surrounding
each installation. However, we
recommend that the lamp and air
filter be cleaned at least once
every three months.
Frequent cleanings will
insure:
1. Maximum germicidal
efficiency.
2. Continued, efficient
filtration performance as a
result of maximum electrostatic
effect.
3. Continued treatment of rated
air capacity as a result of low
filter resistance.
TO CLEAN FILTER:
The filter provided with your Monozone™
Ozone Generator is a permanent,
washable, electrostatic filter.
In most applications, regular
vacuuming will maintain peak
performance. Merely vacuum the
upstream sides first, then
repeat on the discharge side.
Periodically, a thorough flush
with clean water is recommended
to release any dirt not removed
by vacuuming. It is not
necessary to dry the filter
before returning to service -
merely shake off the excess
water and it is ready for use.
When heavy grease concentrations
are encountered, it is advisable
to wash the filter with a
detergent solution to allow the
grease concentration to be
dissolved. The detergent
solution should then be rinsed
thoroughly before the filter is
returned to service. Filters may
be cleaned repeatedly without
physical deterioration or loss
of efficiency.
TO CLEAN OZONE ULTRAVIOLET
LAMP:
The ozone ultraviolet lamps used
in your Monozone™
Ozone Generator, are premium
high output instant start lamps
with 10,000-rated effective
life. For best results, it is
recommended that lamps be
replaced after 10,000 hours
operation.
Lamps should be cleaned
periodically with clean rag and
water or alcohol as even a
slight film or layer of dust
will significantly reduce their
ability to produce ozone.
Inspect carefully to insure that
glass is thoroughly cleaned. It
is recommended that lamps be
cleaned each time the filter
maintenance is performed.
Finally remove any visible dust
from the interior of the Ozone
Generator with a vacuum cleaner
or soft clean cloth. If you have
any questions regarding
installation, operation or
maintenance, please contact the
factory. |
|
|
Monozone™
is a
trademark of the
Atlantic Ultraviolet
Corp. |
|
|
 |
|
|
 |
Copyright 1995-2007 Atlantic
Ultraviolet Corporation. All rights reserved. The information and recommendations contained in this publication are
based upon data collected by the Atlantic Ultraviolet Corporation and are believed to be correct. However, no guarantee or warranty of any
kind, expressed or implied, is made with respect to the information contained herein. Specifications and information are subject to change without notice. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
germicidal bulb, germicidal bulbs,
germicidal lamp, germicidal lamps, germicidal light, germicidal lights,
germicidal ultraviolet lamp, germicidal ultraviolet lamps, ultra violet
lamps, ultra violet water purification, ultraviolet air disinfection,
ultraviolet air purification, ultraviolet air purifiers, ultraviolet air
sanitizer, ultraviolet bulb, ultraviolet bulbs, ultraviolet lamp,
ultraviolet lamps, ultraviolet light bulb, ultraviolet light bulbs,
ultraviolet sterilization, ultraviolet sterilizer, ultraviolet
sterilizers, ultraviolet tube, ultraviolet tubes, ultraviolet water,
ultraviolet water disinfection, ultraviolet water purification,
ultraviolet water purifier, ultraviolet water purifiers, ultraviolet
water sterilizer, ultraviolet water sterilizers, ultraviolet water
treatment, uv air disinfection, uv air duct, uv air purification, uv air
purification system, uv air purifier, uv air purifiers, uv air
sanitizer, uv air sanitizers, uv bulb, uv bulbs, uv disinfection, uv
germicidal lamps, uv lamp, uv lamps, uv light bulb, uv light bulbs, uv
sterilizer, uv sterilizers, uv tube, uv tubes, uv water, purifier, uv
water purifiers, uv water treatment, uvc, uvc bulb, uvc bulbs, uvc
lamps, uvc light, uvc lights, uvc tube, water sterilization, water
sterilizer, water sterilizers,
Atlantic Ultraviolet, Atlantic Ultraviolet Corporation, Atlantic UV,
Atlantic UV Corporation |
|